Cabin Specifications:
Internal: 16' wide x 10'-0.5" high x 28' long
External: 16'-10" wide x 12'-0.5" high x 29' long
-(3) exhaust fans (1/2 HP motor) @ 1200CFM ea.
-(3) intake fans (1/2 HP motor) @ 1000CFM ea.
Dual skin insulated panel construction
- Smooth fit and finish gives the spray booth an impressive overall appearance and minimize areas where overspray and dust could collect
White pre-coated galvanized steel
- White coating diffuses light better than uncoated steel, reducing reflections and glare
- Weld-free construction prevents rusting and improves paintbooth strength
Heavy-duty 4-wing entrance door with observation windows
- One side access door with observation window
Sixteen 6-tube inside-accessible ETL listed light fixtures with energy efficient electronic ballasts
Solid back or drive-thru available
|
|
Eurovac self-locking fume arm:
Self supporting fume arms provide an economical and effective method for the capture of fumes. Contaminants are removed at the source. Arm is equipped with a 1000CFM exhaust fan which is interlocked with cabin exhaust to balance room pressure.
Features:
-Fabricated of steel with cast aluminum joints
- Arm joints include friction discs and are fully adjustable (operator sets the arm tension)
- Arms include handle with completely encircles the hood in order to facilitate easy repositioning from all sides
- 6" diameter x 14' fume arm with 12" hood diameter
- All joints include a 2000Fº rated hose which is gear clamped to the tube
- Hood is equipped for the installation of an optional light and on/off exhaust control
|
Optional Equipment:
Eurovac Accessories
-Swinging extension booms to increase reach by 3 feet to 19.5 feet
- Central dust extraction system
- Eurovac II Sanding Portable
- HEPA filtration
- Conversion kits and airlines
Arm Applications
- All welding processes
- Chemical applications
- Glue fumes, grinding dusts and most air borne dusts |
|
Code Compliance:
NFPA-33 Standard for Spray Application using Flammable or Combustible Materials
NFPA-86 Standard for Ovens and Furnaces
NFPA-91 Standard for Exhaust Systems for Air Conveying of Materials
NFPA-101 Life Safety Code
NFPA-70 National Electric Code
OSHA Safety and Health Standards (29 CFM 1910, 1910.107)
BOCA National Fire Prevention Code; National Building Code
UFC Uniform Fire Code
UBC Uniform Building Code E
SBCCI Standard Fire Prevention Code; Standard Building Code |