GFS’ exclusive SpaceSaver heat system is engineered to provide high-performance in a small package. All shops face the fact that floor space is expensive, and the need to maximize the useable area in your shop is extremely important. By effectively compacting a high-efficiency heat system into the same area as the paint booth cabin, GFS has opened up new possibilities for booth placement and body shop
arrangement for businesses that are short on space.
Dual-skin model pictured
Effective Semi-Downdraft Airflow
GFS designed the SpaceSaver to utilize the proven airflow design of a semi-downdraft paint booth, but integrated the heater and fans into an innovative single-piece unit built into the plenum of the cabin. The SpaceSaver heater moves the air through the filtered ceiling, down over the vehicle, and into the twin exhaust boxes at the rear of the cabin.
Hip-Light T-bar construction ceiling:
This classic downdraft ceiling design is simple in its construction and concept, and yields impressive performance. The full-filtered ceiling provides excellent air filtration and contaminant control, and the integrated hip-style ceiling lights provide excellent illumination inside the cabin.
• 12 high-efficiency 4-tube light fixtures
- 8 lights integrated into hip-light ceiling and 4 sidewall lights
• Dual-skin white pre-coated insulated panel construction
• 3-wing dual-skin insulated entry doors with drive-thru options
SpaceSaver Air Heater:
• Semi-down configuration
• Exhaust yoke
• Recirculation booth
• Air-flow 10,000 CFM
• 100 degree F temp rise
• Exhaust-mounted Variable Frequency Drive
• Aluminum burner (lower
maintenance)
• Maintenance access (booth
ceiling service ports and heater
side access)
Optional AdvanceCure Accelerated Airflow System:
AdvanceCure Accelerated Airflow System is optional on the SpaceSaver. Adding AdvanceCure to the interior of the booth vastly improves the productivity of the equipment. AdvanceCure introduces controlled turbulence into the paint booth during the flash-off and cure cycles to rapidly draw vapors out of the painted surfaces. This increased airflow dramatically reduces the amount of time required for each paint job, and in turn, increases the profitability of your body shop. AdvanceCure speeds curing of both solvent-based and waterborne paints, so you can be sure that your finishing operation will improve today, and well into the future.
Dual-Skin Cabin Specifications:
Internal - 14’ w x 9’ h x 24’ l
External - 15’ 1/2” w x 12’ 9 3/4” h x 27’ l
3-wing Entry Door - 9’8”w x 8’ 8 3/4” h Semi-downdraft airflow during spray and curing cycles through t-bar ceiling with integrated angled hip-style light fixtures
Dual skin insulated panel construction
- White pre-coated galvanized steel
- Weld-free construction prevents rusting and improves spray booth strength
Twin exhaust boxes at rear of cabin compatible with drive-thru door upgrade
Heavy-duty 3-wing entrance door with observation windows, Side access door with observation window, can be moved to accommodate different spraybooth layouts
Eight 4-tube ceiling light fixtures, Four 4-tube sidewall light fixtures with energy efficient electronic ballasts
Spray booth is designed to accept fire suppression system
Single-Skin Cabin Specifications:
Internal - 14’ w x 9’ h x 24’ l
External - 15’ 1/2” w x 12’ 9 3/4” h x 27’ l
3-wing Entry Door - 9’8”w x 8’ 8 3/4” h Semi-downdraft airflow during spray and curing cycles through t-bar ceiling with integrated angled hip-style light fixtures
Single-skin rolled-edge panel construction
- White pre-coated galvanized steel
- Weld-free construction prevents rusting and improves spray booth strength
Twin exhaust boxes at rear of cabin compatible with drive-thru door upgrade
Heavy-duty 3-wing entrance door with observation windows, Side access door with observation window, can be moved to accommodate different spraybooth layouts
Eight 4-tube ceiling light fixtures, Four 4-tube sidewall light fixtures with energy efficient electronic ballasts
Spray booth is designed to accept fire suppression system
Optional Equipment:
- Drive-thru configurations
- Working length extensions
- Fire suppression system
- AdvanceCure Accelerated Airflow System
Code Compliance:
NFPA-33 Standard for spray application using flammable or combustible materials
NFPA-86 Standard for ovens and furnaces
NFPA-91 Standard for exhaust systems for air conveying of materials
NFPA-101 Life Safety Code
NFPA-70 National Electric Code
OSHA Safety and Health Standards (29 CFR 1910, 1910.107)
IFC International Fire Code
IBC International Building Code
IMC International Mechanical Code
BOCA National Fire Prevention Code; National Building Code; National Mechanical Code
UFC Uniform Fire Code
UBC Uniform Building Code
UMC Uniform Mechanical Code
SBCCI Standard Fire Prevention Code; Standard Building Code; Standard Mechanical Code
Global Finishing Solutions 12731 Norway Road • Osseo, WI • 54758 P800-848-8738 • F715-597-2193 • info@globalfinishing.com